N J L M

 
Subscribe Via RSS
  • Home
  • About
    Salient Features Bibliographic Information Abstracting and Indexing Specialties Covered Publisher Journal Policy
  • Issues
    Current Issue Online Ahead of Print Archive Forthcoming issue
  • Editorial
    Editorial Statements Editorial-PeerReview Process Editorial Board Publication Ethics & Malpractice Join us
  • Authors
    Submit an Article Manuscript Instructions Manuscript Assistance Publication Charges Paid Services Early Online Publication Service
  • Reviewers
    Apply as Reviewer Reviewers Acknowledgment
  • Search
    Simple Search Advanced Search
  • Member
    Register Login
  • Contact
  • Subscription
Original article / research
Year: 2024 Month: July Volume: 13 Issue: 3 Page: BO04 - BO07

Comparison of Sample Size and Rejection Limits for Lot-to-Lot Verification using Two Different Protocols: A Cross-sectional Study

 
Correspondence R Arun Krishnan, S Jaya Kumari, Saranya Raj,
S Jaya Kumari,
E-604, Raheja Residency, 3rd Block, Koramangala, Bengaluru-560034, Karnataka, India.
E-mail: jaya_kripal@yahoo.com
:
Introduction: Good laboratory practice necessitates verifying each new lot of reagents before it is put into service to ensure that the results of patient samples are consistent across different lots of reagents. Current laboratory protocols use uniform criteria such as a 10% difference, measurement uncertainty, etc., for the acceptance of Lot-to-Lot Verification (LTLV) across all parameters. Although a detailed guideline was introduced by the Clinical and Laboratory Standards Institute (CLSI), there is limited literature on laboratories using this.

Aim: To compare the sample size and rejection limits for LTLV for common chemistry analytes using two different protocols.

Materials and Methods: The present cross-sectional analytical study was carried out in the Department of Biochemistry, St. John’s Medical College, Bengaluru, Karnataka, India, from January 2017 to January 2019. The LTLV for reagents was done using patient and Internal Quality Control (IQC) data for common analytes such as glucose, creatinine, albumin and calcium on Siemens Dimension EXL 200 chemistry analyser. Sample size and rejection limits obtained using CLSI EP26-A guidelines were compared with one of the current protocols, which uses one sample at each concentration, usually a maximum of two at two different concentrations, and defines less than a 10% difference in value between the two lots as acceptable criteria. The quality control data was analysed, and descriptive statistics such as the coefficient of variation were used to arrive at precision. Rejection limit and sample size were directly read from the EP26-A guideline using the tables given for the same, based on the two ratios at 90% power.

Results: The sample size needed was found to be the same for creatinine and albumin using both protocols, while it was higher for glucose and calcium based on EP26-A guideline. The rejection limit obtained using EP26-A guideline was different for each parameter between the two protocols. The rejection limit obtained using EP26-A was lower for all analytes as compared to the first protocol.

Conclusion: Lot-to-Lot Verification (LTLV) using the CLSI guideline reinforces the fact that the sample size needed and the rejection limit for each parameter varies based on its performance and the critical difference to be detected. Hence, the practice of using a fixed sample size and fixed criteria, such as a 10% acceptable difference across all parameters, may not be appropriate.
 
[ FULL TEXT ]   |   [ ]
 
Print
  • Article Utilities

    • Readers Comments (0)
    • Article in PDF
    • Citation Manager
    • Article Statistics
    • Link to PUBMED
    • Print this Article
    • Send to a Friend
    • Go To Issues

      • Current Issue
      • Past Issues
  • Search Articles

    • Simple Search
    • Advance Search
  • Authors Facilities

    • Extensive Author Support
    • Submit Manuscript
    • ONLINE First Facility
    • NJLM Pre Publishing
  • Quick Links

    • REVIEWER
    • ACCESS STATISTICS
  • Users

    • Register
    • Log in
  • Pages

    • About
    • Issues
    • Editorials
    • Authors
    • Reviewers
    • Search
    • Contacts
  • Issues Archives

  • Affiliated Websites

    • JCDR Prepublishing
    • Neonatal Database Home
    • JCDR Neonatal Database download center