N J L M

 
Subscribe Via RSS
  • Home
  • About
    Salient Features Bibliographic Information Abstracting and Indexing Specialties Covered Publisher Journal Policy
  • Issues
    Current Issue Online Ahead of Print Archive Forthcoming issue
  • Editorial
    Editorial Statements Editorial-PeerReview Process Editorial Board Publication Ethics & Malpractice Join us
  • Authors
    Submit an Article Manuscript Instructions Manuscript Assistance Publication Charges Paid Services Early Online Publication Service
  • Reviewers
    Apply as Reviewer Reviewers Acknowledgment
  • Search
    Simple Search Advanced Search
  • Member
    Register Login
  • Contact
  • Subscription
Original article / research
Year: 2023 Month: January Volume: 12 Issue: 1 Page: BO17 - BO19

Diagnostic Accuracy of Heart-type Fatty Acid Binding Protein for the Detection of Acute Myocardial Infarction among South Indian Population: A Cross-sectional Study

 
Correspondence S Shenbaga Lalitha, A Sankar, G Purushothaman, Chaganti Sridevi,
Dr. G Purushothaman,
14, Kalpavariksha Apartments (Second Floor), Mahadevan Street, Nehru Nagar, Chrompet, Chennai, Tamil Nadu, India.
E-mail: puruganesan@gmail.com
:
Introduction: Acute Myocardial Infarction (AMI) is a serious life threatening condition having a high mortality and morbidity rate. Hence, early detection and appropriate treatment is essential. Clinically Troponin I and Creatinine Kinase Myocardial Band (CK-MB) are currently used to detect AMI. But its rise in blood concentrations is seen only after 4-6 hours after the onset of AMI. Clinical research shows that Heart-type Fatty Acid Binding Protein (H-FABP), a novel biomarker, is beneficial in the early detection of AMI.

Aim: To determine the diagnostic accuracy of H-FABP and compare with the existing blood biochemical markers, such as Troponin I and CK-MB, in the early detection of AMI in south Indian population.

Materials and Methods: This cross-sectional study was conducted in Sree Balaji Medical College and Hospital, south Chennai, Tamil Nadu, India, from March 2017 to April 2019. A total of 50 participants, aged between 40-75 years, and diagnosed with ST elevation myocardial infarction presenting within 24 hours to the emergency room were included. Serum was collected during the time of admission (0 hour), between 4-6 hours from the time of admission and between 12-24 hours from the time of admission for estimation of cardiac specific biomarkers such as cardiac troponin I, H-FABP, CK-MB. The sensitivity, specificity and accuracy of the cardiac-specific biomarkers were calculated using Receiving Operating Characteristics (ROC) curve analysis.

Results: There were 38 males and 12 females, with a mean age of 62.1±4.7 years. The sensitivity of H-FABP at the time of admission (0 hour) was 88%, 78% between 4-6 hours of admission, and 42% between 12-24 hours of admission. At 0 hour, the sensitivity of H-FABP (88%) was high compared to cardiac troponin I (43%) and CK-MB (40%). The accuracy of H-FABP and cTnI was equal (80% each) at the time of admission. At 4-6 hours after admission, cardiac troponin I showed higher sensitivity, specificity and accuracy compared to H-FABP. ROC analysis showed the Area Under the Curve (AUC) for H-FABP was higher (0.81) compared to cardiac troponin I and CK-MB.

Conclusion: The H-FABP was found to be more sensitive compared to cardiac troponin I or CK-MB in AMI patients. Hence, early diagnosis of AMI is made possible with the H-FABP measurements.
 
[ FULL TEXT ]   |   [ ]
 
Print
  • Article Utilities

    • Readers Comments (0)
    • Article in PDF
    • Citation Manager
    • Article Statistics
    • Link to PUBMED
    • Print this Article
    • Send to a Friend
    • Go To Issues

      • Current Issue
      • Past Issues
  • Search Articles

    • Simple Search
    • Advance Search
  • Authors Facilities

    • Extensive Author Support
    • Submit Manuscript
    • ONLINE First Facility
    • NJLM Pre Publishing
  • Quick Links

    • REVIEWER
    • ACCESS STATISTICS
  • Users

    • Register
    • Log in
  • Pages

    • About
    • Issues
    • Editorials
    • Authors
    • Reviewers
    • Search
    • Contacts
  • Issues Archives

  • Affiliated Websites

    • JCDR Prepublishing
    • Neonatal Database Home
    • JCDR Neonatal Database download center